OEM/ODM Manufacturer 160 Kw Gas Generator - product specifications for 160KW natural gas / biogas generator – Naipute
Genset Model 160GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 160/200 Rated Current ( A ) 288 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time ≤5 ... -
Fast delivery Generator Biomass - Product Specifications For 800KW Biomass Gas Generator – Naipute
Genset Model 800GFT – J Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 800/1000 Rated Current ( A ) 1440 Rated Voltage ( V ) 230/400 Rated Frequency(Hz) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilizati... -
Factory best selling Cheapest Natural Gas Generator - Product Specifications For 80kw Natural Gas / Biogas Generator – Naipute
Genset Model 80GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 80/100 Rated Current ( A ) 144 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Freque... -
2020 Good Quality Lpg Gas Generator Price - Product Specifications For 280KW LPG Gas Generator – Naipute
Genset Model 280 GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 280/350 Rated Current ( A ) 504 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time ≤5... -
Special Design for Natural Gas Powered Generators - Product Specifications For 100KW Natural Gas / Biogas Generator – Naipute
Genset Model 100GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 100/125 Rated Current ( A ) 180 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time ≤5 ... -
OEM/ODM Manufacturer Cost Of Natural Gas Generator - Product Specifications For 1000KW Natural Gas / Biogas Generator – Naipute
Genset Model 1000GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 1000/1250 Rated Current ( A ) 1800 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time... -
New Fashion Design for Gas Fired Generator - Product Specifications For 280KW LPG Gas Generator – Naipute
Genset Model 280 GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 280/350 Rated Current ( A ) 504 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time ≤5... -
New Arrival China Natural Gas Generator Conversion - Product Specifications For 1000KW Natural Gas / Biogas Generator – Naipute
Genset Model 1000GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 1000/1250 Rated Current ( A ) 1800 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time... -
PriceList for 30 Kw Biomass Generator - Product Specifications For 260KW Biomass Gas Generator – Naipute
Genset Model 260GFT – J1 Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 260/325 Rated Current ( A ) 468 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilizati... -
Original Factory Automatic Natural Gas Generator - Product Specifications For 50KW Natural Gas/Biogas Generator – Naipute
Genset Model 50GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 50/62.5 Rated Current ( A ) 90 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Freque... -
2020 Good Quality Lpg Gas Generator Price - Product Specifications For 10 Kw LPG Gas Generator – Naipute
Genset Model 10GFT Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 10/12.5 Rated Current ( A ) 18 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilization Time ≤5 S ... -
Factory Cheap Hot Biogas Power Plant - Product Specifications For 400KW Biomass Gas Generator – Naipute
Genset Model 400GFT – J Structure integrated Exciting Method AVR Brushless Rated Power ( kW/kVA ) 400/500 Rated Current ( A ) 720 Rated Voltage ( V ) 230/400 Rated Frequency ( Hz ) 50/60 Rated Power Factor 0.8 LAG No Load Voltage Range 95% ~ 105% Stable Voltage Regulation Rate ≤±1% Instantaneous Voltage Regulation Rate ≤-15% ~ +20% Voltage Recover Time ≤3 S Voltage Fluctuation Rate ≤±0.5% Instantaneous Frequency Regulation Rate ≤±10% Frequency Stabilizatio...